Skud Technical Case Study Cleanroom Performance Testing Malaysia
Case study · Cleanroom Performance Testing

Cleanrooms in Malaysia, certified to ISO 14644 across sectors.

Independent Cleanroom Performance Testing and ISO 14644 classification for medical device and electronics facilities in Penang, Malaysia, each zone proven against the class it was designed to hold.

Cleanroom Performance Testing Penang, Malaysia ISO 14644 NEBB methodology
Project snapshotSKUD
ServiceCleanroom Performance Testing
SectorsMedical device, electronics
LocationPenang, Malaysia
ClassesISO 14644, to each zone's design class
MethodNEBB cleanroom procedural standard
OutcomeEach facility certified to class
Scope at a glance

One test discipline, applied across sectors.

ISO 14644
Classification to the class each cleanroom was designed to hold
Full suite
Every governing parameter measured, not particle count alone
Zone by zone
Each area proven against its own class, not sampled as a group
Independent
Skud did not design, install, or commission any of it
The brief

Prove the environment, not just the particle count.

Across a medical device facility and an electronics facility in Penang, Malaysia, Skud was engaged to test and certify cleanroom performance to ISO 14644. Different sectors, different cleanliness classes, one common requirement: an independent record that each controlled environment performs to the class it was designed for.

Because Skud does not design, install, or commission cleanrooms, the certification answers only to the standard. The result is a document a quality auditor or regulator can accept without asking who had an interest in the outcome.

The challenge

A cleanroom is only as certified as its weakest reading.

  • Classification is the headline, but it is not the whole test. A room can pass its particle count and still fail on recovery, pressure, or filter integrity, and a fail on any one is a fail.
  • Different sectors, different targets. A medical device line and an electronics cleanroom do not hold the same class, so each was tested against its own design intent rather than a single benchmark.
  • Working around live and sensitive operations, without disturbing what each facility was built to protect.
Full test scope

Every certification regime, not a particle count alone.

Cleanroom certification is the sum of its parameters. Across the facilities tested, the scope covered:

  • Airflow velocity and air change rate
  • Airborne particle count and ISO 14644 classification
  • HEPA filter leak testing, by PAO challenge or ambient scan
  • Room differential pressure
  • Temperature and relative humidity
  • Floor resistance, point to point and point to ground
  • Sound and light levels
The outcome

Every facility certified to class, fully documented.

Each cleanroom was certified to its ISO 14644 class against the full governing parameter set, with detailed documentation delivered to meet each facility's regulatory and operational requirements. Every certificate rests on one method and one standard of independence, which is what makes a Skud cleanroom certificate mean the same thing on every site.

Worked to ▸ ISO 14644-1, -2 and -3 ▸ NEBB Procedural Standard for Certified Testing of Cleanrooms ▸ IEST Recommended Practices
Cleanroom to certify?

Independent, NEBB-certified cleanroom performance testing to ISO 14644.