Service · Independently certified

Cleanroom Performance Testing that proves your environment holds its class.

Independent classification and qualification of controlled environments to ISO 14644 and EU GMP. Particle counts, filter integrity, airflow, and pressure, measured and certified so audits and handover pass on the first submission. For semiconductor fabs, pharmaceutical plants, hospitals, laboratories and any facility that depends on a cleanroom.

Certified to NEBB, the National Environmental Balancing Bureau, whose international standard governs cleanroom performance testing. The first firm in Malaysia certified by NEBB in both Testing, Adjusting & Balancing and Cleanroom Performance Testing.

Cleanroom readoutISO 14644 ▸ SKUD
Class
Airborne particles, ≥0.5 µm · at rest
247,000 /m³
0Sample within classClass limit 352,000
ISO classificationClass 7Pass
HEPA penetration<0.01%Pass
Typical air change rate30–60 ACHDesign ref
Tested to ▸ ISO 14644-1, -2 & -3 ▸ EU GMP Annex 1 ▸ IEST Recommended Practices
The service

What cleanroom testing actually verifies.

Cleanroom testing is the disciplined process of measuring, classifying, and documenting that a controlled environment holds its particle, airflow, and pressure limits, at rest and in operation.

A built cleanroom is not a qualified cleanroom. Filters can be installed and fans running, yet a single leaking seal or a lost pressure cascade quietly puts the whole room out of class. Testing is the step that turns "it is built" into "it performs, and here is the data."

Because Skud does not build or fit out the rooms we test, our results carry no conflict of interest. The figures in a Skud report are the figures a QA team, consultant, or auditor can sign against.

Classify

Measure airborne particle concentrations and assign the ISO 14644-1 class, at rest and in operation.

Qualify

Prove HEPA/ULPA integrity, airflow, pressure cascade, and recovery against the design specification.

Monitor

Set baselines and a requalification schedule so the room stays compliant across its whole life.

Scope of work

Particles, airflow, and the environment, qualified as one system.

Cleanroom integrity is decided across the whole chain, from filter face to occupancy. We cover the full ISO 14644-3 test suite, not just the particle count.

Particles & filters

Particle count & filter integrity

  • Airborne particle classification (ISO 14644-1)
  • HEPA / ULPA leak test (DOP / PAO)
  • Filter installation leak scan
  • Recovery & clean-up rate test
  • At-rest & in-operation classification
Airflow & pressure

Airflow & pressurisation

  • Air velocity & uniformity
  • Air change rate (ACH)
  • Unidirectional flow visualisation (smoke)
  • Room pressure cascade
  • Containment & enclosure leak test
Standards & references ▸ ISO 14644-1, -2 & -3 ▸ EU GMP Annex 1 ▸ IEST Recommended Practices
Audit or handover due?

Send us the scope and get an independent cleanroom testing proposal.

How it runs

A documented method, from test plan to certified classification.

Every engagement follows the same disciplined sequence, so the data is traceable and the report stands up to a GMP audit.

Plan & calibrate

Review URS and classification targets, agree the test plan and acceptance criteria, and calibrate every instrument with traceable certificates.

Test & classify

Particle counts, filter integrity, airflow, pressure, and recovery measured at defined sample locations, at rest and in operation.

Diagnose & rectify

Any failure is traced to its cause, filter seating, leakage, or imbalance, with clear corrective actions, then retested to confirm the fix.

Certify & report

An ISO 14644 and NEBB-format certified report with classification statement, ready for QA, consultant, and auditor sign-off.

Deliverables

What you receive at qualification.

A test report is only as good as its evidence. Ours is built to be read, audited, and signed.

Certified performance report

ISO 14644 and NEBB-format report with a signed classification statement, ready for QA, consultant, and auditor acceptance.

Particle count data

Airborne particle counts at every sample location, recorded both at rest and in operation.

HEPA / ULPA integrity results

Filter integrity recorded per filter against pass thresholds, so every barrier is accounted for.

Calibration certificates

A traceable calibration certificate behind every instrument, so every figure can be independently verified.

Deficiency log

Every failure listed with its corrective action and retest confirmation, so nothing stays open at qualification.

Marked-up drawings

Room drawings marked up with sample locations and final results, recording the room exactly as qualified.

Why independent testing

Independent qualification, from a firm with no stake in the room.

One traceable set of results that QA, consultants, and auditors can all work from, so acceptance rests on the data rather than on whose data it is.

01 / Independence

No conflict of interest

We do not build, fit out, or supply the rooms we test. Our results answer to the data, not to a programme deadline.

02 / Traceability

Defensible data

Calibrated instruments and a documented method mean every figure can be traced, and holds up in a GMP audit or dispute.

03 / Acceptance

Built for sign-off

Reports are formatted for QA, consultant, and regulator acceptance, so qualification is not held up by avoidable questions.

Independently certified

NEBB cleanroom certification, from the first dual-certified firm in Malaysia.

The National Environmental Balancing Bureau sets the international standard for cleanroom performance testing. It is the credential specifiers ask for by name on regulated and mission-critical work, and the benchmark an independent report is measured against. Every NEBB cleanroom certification report states the ISO class achieved, the occupancy state tested, and the measured data behind each result.

Issuing bodyNational Environmental Balancing Bureau (NEBB)
DisciplineCleanroom Performance Testing (CPT)
StandingFirst firm in Malaysia certified in both Testing, Adjusting & Balancing and Cleanroom Performance Testing
Firm cert no.3921
NEBB Certified Firm certificate issued to Skud Technical Sdn Bhd for Cleanroom Performance Testing
Where it matters most

Environments where contamination is the risk.

Pharma & biotech
Hospitals & healthcare
Semiconductor & electronics
Medical devices
Labs & research
Food & cosmetics
Cleanroom testing

Cleanroom testing and certification, planned around production.

A cleanroom is tested at three points in its life: at handover, at routine requalification, and after any change that could affect its class, such as a filter replacement, a layout change or a shutdown.

Testing follows ISO 14644-1 and ISO 14644-3, with EU GMP Annex 1 and client specifications applied where they govern. We plan each visit around your production schedule, so rooms go back into service as quickly as possible.

Our teams work from Kuala Lumpur, Johor Bahru and Penang, and deliver projects across Sabah, Sarawak, Singapore and the wider Asia region.

Common questions

Cleanroom performance testing, answered plainly.

What is the difference between cleanroom classification, qualification and certification?

Classification measures airborne particle concentrations and assigns the cleanroom an ISO class in accordance with ISO 14644-1. It answers one question: how clean is the air, and which class does that correspond to.

Qualification is the wider set of tests that demonstrates the room performs as designed. Alongside particle counts it covers HEPA and ULPA filter integrity, air velocity and air change rate, room pressure cascade, recovery and, where required, airflow visualisation. In regulated facilities this normally sits within the project’s installation, operational and performance qualification documentation.

Certification is the formal issue of the results. The testing body states which tests were performed, the measured values, the acceptance criteria applied and whether each was met, and signs the report. That certificate is what a QA team, consultant or auditor works from.

In short, classification is a measurement, qualification is a programme of tests, and certification is the documented outcome. The scope required on a given project should be confirmed against the specification and applicable regulatory requirements.

How often should a cleanroom be requalified?

There is no single requalification interval that applies to every cleanroom. ISO 14644-2 requires monitoring and review to be based on the room’s intended use, performance data and risk assessment.

For sterile pharmaceutical facilities governed by EU GMP Annex 1, the maximum interval is six months for Grade A and B areas and 12 months for Grade C and D areas. Requalification may also be required after significant modifications, repairs, remedial work or changes that could affect cleanroom performance. Other industries should follow the project specification, quality system and applicable regulatory requirements.

What do “at rest” and “in operation” mean?

At rest means the cleanroom installation is complete and the HVAC system and relevant equipment are operating, but no personnel are carrying out production activities inside the room.

In operation means the cleanroom is functioning under its normal defined conditions, with the specified number of personnel, equipment and processes operating.

A room may meet its required particle class at rest but perform differently during normal operations. The required occupancy state should therefore be agreed before testing based on the applicable standard, room use and project specification.

Will Skud travel to our cleanroom facility?

Yes. Skud provides cleanroom performance testing throughout Malaysia from our Kuala Lumpur, Johor Bahru and Penang operations. We mobilise full certified teams overseas, with cleanroom certification already delivered in Brunei and India, and we mobilise for projects across Southeast Asia and beyond, including Indonesia, Thailand and China.

Send us the project location, required cleanroom class, room quantities, testing scope and target dates. Our team will review the information and prepare the proposed test plan, programme and commercial scope.

Is NEBB cleanroom certification recognised in Malaysia?

NEBB is an international certification association for specialist disciplines including Cleanroom Performance Testing. It is not a Malaysian regulator, and project acceptance ultimately depends on the contract specification, consultant, owner, quality team and applicable regulatory requirements.

As a NEBB-certified Cleanroom Performance Testing firm, Skud performs testing using documented procedures, calibrated instruments and traceable reporting. Our testing can be aligned with NEBB procedural requirements, ISO 14644, EU GMP and the project’s specified acceptance criteria.

What does cleanroom certification include?

A typical scope covers airborne particle counts for ISO classification, HEPA and ULPA filter leak testing, airflow velocity and air change rate, room pressure differentials, recovery testing, airflow visualisation, and temperature and humidity. The exact scope depends on your ISO class, the occupancy state and any regulatory requirements.

How is cleanroom testing priced?

By the number of rooms, their ISO class, the tests required and the occupancy state. Send us the room list and layout and we will return a fixed proposal within 24 hours.

Get a proposal

Certify your cleanroom. Get the evidence for sign-off.

Independent cleanroom performance testing against ISO 14644, project specifications and agreed acceptance criteria. We test the required parameters, document the results and issue a clear certification report for handover, audit or regulatory review..

  • Testing aligned with ISO 14644 and project requirements
  • Clear pass, fail and deficiency findings for every room
  • Certification reports prepared for handover and audit review

WhatsApp · Service desks

Contact Form 2 Column