Service · Field certification

Biosafety cabinet and clean-air equipment certification, verified to protect people and product.

Independent field certification of biosafety cabinets, laminar airflow units, fume hoods, and clean-air equipment. We test containment, airflow, and filter integrity to the recognised standard, so the device is proven safe to use, not just switched on.

Biosafety cabinet certification is carried out by an NSF/ANSI 49 accredited field certifier, and Skud is a NEBB (National Environmental Balancing Bureau) certified firm for cleanroom performance testing, so every device is verified to a standard auditors recognise.

Device readoutNSF/ANSI 49 ▸ SKUD
Device
Class II BSC · inflow velocity
0.53 m/s
0.45Within tolerance0.55
Downflow velocity0.34 m/sPass
HEPA integrity<0.01% penPass
DeviceClass II Type A2Ref
Certification
credentials
▸ NEBB Certified Firm Cleanroom Performance Testing · Cert 3921 ▸ NSF/ANSI 49 Cabinets certified by accredited field certifier
The service

What equipment certification actually verifies.

Certification is the measured proof that a cabinet or clean-air device is containing, filtering, and moving air the way its safety depends on, not just powered on and humming.

A biosafety cabinet can look and sound like it is working while a failed seal, a loaded filter, or a drifted fan quietly lets containment slip. The people at the bench and the product inside have no way to see it. Field certification is the test that makes the invisible measurable.

Skud only tests. We do not sell, install, or repair the equipment we certify, so the result carries no conflict of interest. A Skud certificate is the independent proof an auditor, safety officer, or QA team accepts.

Contain

Verify inflow and containment so hazardous aerosols stay inside the cabinet and away from the operator.

Filter

Test HEPA integrity for leaks, so the air leaving the device is genuinely clean, not just filtered on paper.

Certify

Measure airflow, smoke pattern, and safety functions, then certify and label the device with its next test due.

Equipment we certify

One independent team for the whole clean-air inventory.

From biosafety cabinets to fan filter units, we certify the containment and clean-air devices across your facility.

Class II biosafety cabinets Class I biosafety cabinets Class III biosafety cabinets Cytotoxic drug safety cabinets Horizontal laminar airflow cabinets Vertical laminar airflow cabinets Clean benches Ducted fume hoods Ductless fume hoods Fan filter units (FFU) HEPA housings & terminals Laminar flow booths Weighing & dispensing booths Downflow booths Static pass boxes Dynamic pass boxes Isolators & glove boxes

Device not on the list? If it contains, filters, or moves clean air, we can most likely certify it. Send us the model and we will confirm.

WhatsApp our team
Scope of work

Containment, filtration, and safety, tested as one.

Each device is put through the full field-certification suite for its type, not a partial check.

Containment

Airflow & containment

  • Inflow & face velocity
  • Downflow velocity & uniformity
  • Airflow smoke pattern test
  • Site & installation assessment
Filtration

HEPA filter integrity

  • HEPA / ULPA leak test (DOP / PAO)
  • Filter installation seal scan
  • Filter loading & replacement advice
  • Discharge air cleanliness
Safety

Safety & environment

  • Alarm & safety interlock function
  • Sash position & airflow alarm
  • Light & noise level measurement
  • Electrical safety check
Standards & references ▸ NSF/ANSI 49 ▸ EN 12469 ▸ ISO 14644 ▸ IEST-RP-CC034 & CC002
Cabinets due for recertification?

Send us the device list and get a fixed certification proposal.

How it runs

A field-certification method that ends in a labelled device.

Every device follows the same disciplined sequence, on site, so the result is traceable and the certificate stands up.

Assess & set up

Confirm device type and location, check installation and siting, and verify every instrument before testing.

Test to standard

Run the full airflow, containment, HEPA integrity, and safety-function suite for the device type against its acceptance limits.

Diagnose & advise

Any fail is recorded with its measured value and a clear cause, with filter or adjustment advice so it can be put right and retested.

Certify & label

Issue the test report and certificate, and fix a dated label to each passing device showing its next test due.

Deliverables

What you receive per device.

A certificate is only as good as its evidence. Ours is built to be read, audited, and signed.

Device inventory summary

A single summary across the full mobilisation, so the whole inventory is accounted for in one place.

Individual test reports

One report per device, recording every measured value against its acceptance limit.

Airflow & HEPA data

Airflow velocity data and HEPA integrity results for every applicable device.

Smoke, light & noise

Smoke pattern observations plus light and noise measurements where the method calls for them.

Non-conformance list

Any deviation listed with its measured value and the acceptance limit, so the fix is clear.

Certification label

A dated certification label on each passing device, carrying its next test due date.

Why proper certification matters

A cabinet that fails quietly puts people and product at risk.

Independent field certification turns an assumption of safety into measured, defensible proof.

01 / Protection

People and product

Verified containment keeps hazardous aerosols off the operator, and verified clean air keeps contamination out of the product. Both are invisible until they fail.

02 / Compliance

Audit and GMP ready

Certification to the recognised standard keeps you ready for GMP, biosafety, and lab-accreditation audits, with a documented record and clear recertification dates.

03 / Independence

No conflict of interest

We only test. Because we do not sell, install, or repair the equipment we certify, our result is genuinely independent, the kind auditors and safety officers accept.

Industries we serve

Wherever containment and clean air are non-negotiable.

Pharma & life science
Hospitals & healthcare
Research & diagnostics labs
Biotech & vaccines
Food & cosmetics
Universities & institutions
Common questions

Equipment and cabinet certification, answered plainly.

How often should a biosafety cabinet be certified?

A biological safety cabinet should normally be field-certified at least annually, as well as after initial installation, relocation, repairs or changes that may affect its performance. Certification should also be repeated after HEPA filter replacement or other significant internal work.

Each cabinet is labelled with its certification status and next recommended certification date, giving the facility a clear record for safety management and audit planning. NSF/ANSI 49 provides the recognised field-testing procedures for Class II biosafety cabinets.

What does biosafety cabinet certification include?

The required tests depend on the cabinet type and applicable standard. A typical field-certification scope may include:

  • Inflow and downflow velocity
  • HEPA filter integrity
  • Airflow smoke-pattern testing
  • Cabinet installation assessment
  • Alarms and operating controls
  • Lighting, noise and vibration, where required

The purpose is to verify that the cabinet continues to provide the required level of personnel, product and environmental protection. Our guide to biosafety cabinet testing explains each test in detail.

Does Skud sell or repair laboratory equipment?

Skud does not sell laboratory equipment. We test and certify it, and we also carry out HEPA filter replacement and repairs on biosafety cabinets and clean air devices.

When equipment does not meet the applicable acceptance criteria, we document the measured results and identify the area requiring investigation. Skud can then replace the filters or complete the repair and retest the equipment, or your supplier or maintenance contractor can do the corrective work before Skud returns to retest.

What happens if equipment fails certification?

The equipment will not be certified as compliant. Skud issues a clear record showing the failed test, measured result and applicable acceptance limit.

The findings may indicate issues involving airflow, HEPA filter integrity, cabinet installation, controls or other performance conditions. Because testing does not always establish the exact mechanical cause, further inspection may be required. Skud can carry out filter replacement and repairs, or your equipment supplier or maintenance contractor can do the work.

Once corrective work is completed, Skud can retest the affected equipment. A certificate and status label are issued only after the required acceptance criteria have been achieved.

Can Skud test an entire facility in one mobilisation?

Yes. Skud can plan a coordinated mobilisation for facilities with multiple units, including:

  • Biological safety cabinets
  • Laminar airflow cabinets and clean benches
  • Fume hoods
  • Fan filter units
  • Other controlled-environment equipment within the agreed scope

Each unit is individually identified and tested against the applicable requirements. Skud can then provide individual test records together with a consolidated equipment register showing the location, equipment reference, result and next recommended test date.

Send us the equipment list, cabinet types, locations and required completion date, and we will prepare the testing programme and commercial scope.

Get a proposal

Get every cabinet certified and ready for service.

Send us your equipment list, site location and preferred testing dates. We will confirm the required tests, applicable standards and a programme that works around your laboratory operations.

  • Biosafety cabinets tested to NSF/ANSI 49 requirements
  • Certificates and certification labels issued for compliant equipment
  • Deficiencies clearly documented for rectification and retesting

WhatsApp · Service desks

Contact Form 2 Column